
Growatt SYN 200-XH-US-11A
Growatt — the world's #1 residential solar inverter brand by Wood Mackenzie. The SYN 200-XH-US-11A is a utility-scale hybrid storage inverter (100–600 kVA). Designed for mini-grids, utility BESS, and large diesel-genset hybrids in mining, telecom hubs, and off-grid resorts.
- Max. AC input current protection: 200A
- Max. continuous input current: 160A
- AC output voltage (Nominal): 240V
In stock
Growatt SYN 200-XH-US-11A features
About the Growatt SYN 200-XH-US-11A
Growatt — the world's #1 residential solar inverter brand by Wood Mackenzie. The SYN 200-XH-US is a utility-scale hybrid storage inverter (100–600 kVA). Designed for mini-grids, utility BESS, and large diesel-genset hybrids in mining, telecom hubs, and off-grid resorts. Key features: grid-forming, IP66, multi-MPPT. 10-year warranty. Available across the Middle East, Europe, and Africa via Growatt MJS Solutions, the authorised distributor based in Dubai. Remote monitoring via the ShinePhone app and ShineServer cloud — view performance from anywhere, configure alerts, and manage multiple sites. This model: SYN 200-XH-US-11A.
Specifications last updated 1 May 2026
Growatt SYN 200-XH-US-11A full specifications
Electrical
| Max. AC input current protection | 200A |
|---|---|
| AC output voltage (Nominal) | 240V |
| Interrupting rating | 240V – 50kA |
| AC output voltage range | 180-270V |
| Grid disconnection switchover time | <500ms |
| Max. AC current output | 200A |
| AC L-L output voltage (Nominal) | 240V |
| AC L-L output voltage range | 180-270V |
| AC frequency (Nominal) | 60Hz |
| AC frequency range | 55-65Hz |
| Max. inverters AC current output in backup operation | 48A |
| Imbalance compensation in backup operation | 3000W |
| AC L-N output voltage in backup (Nominal) | 120V |
| AC L-N output voltage range in backup | 105-132V |
| AC frequency range in backup | 55-65Hz |
| Max. rated AC power | N/A |
| Max. continuous input current | 160A |
| Dry contact switch voltage rating | N/A |
| Dry contact switch current rating | N/A |
| 2-wire Start | N/A |
| Communication | RS485 |
| Service rated | Yes |
| Manual control bypass switch | Yes |
| Energy meter (for import/export) | 1% accuracy |
| Cooling | Natural convection |
| Noise | <35dB |
| Operating temperature range | -40°C~+50°C (-40°F~+122°F) |
| Protection rating | IP65/NEMA Type 4X |
| Operating humidity (RH) | Up to 100% |
| Maximum elevation | 3000m (9843ft) |
| Mounting options | Wall mount |
| Weight | 26.7kg (58.86lbs) |
| Dimensions (W/H/D) | 445/550/160mm (17.52/21.65/6.30in) |
| Safety | UL1741, CSA 22.2 NO. 107, UL869A |
| EMC (Emissions) | FCC part15 class B |
Certifications
- UL1741, CSA 22.2 NO. 107, UL869A
- FCC part15 class B
Related Products

SYN 200-XH-US-13A
- Max. AC input current protection:200A
- Max. continuous input current:160A

SYN 100-XH-30
- Max. AC input overcurrent protection:125A
- Max. continuous input current:90A

EU SYN 600E-30
- Max. AC apparent power:330kVA
- Nominal AC voltage:380/400/415V

NEO 1600M-X2
- Max. recommended PV power (for module STC):320W to 530W+
- Max. DC voltage:60V
Related Articles
Growatt vs Deye Inverters — Full 2026 Comparison for UAE and KSA Buyers
Detailed growatt vs deye inverters comparison: efficiency, battery flexibility, monitoring (ShinePhone vs SolarMan), warranty, regional support across the Gulf.
Read: Growatt vs Deye Inverters — Full 2026 Comparison for UAE and KSA Buyers →Growatt Time of Use Solar Net Metering — Programming SPH for DEWA and SEC TOU Tariffs
Growatt time of use solar net metering: program SPH inverters via ShinePhone for DEWA Shams Dubai TOU and SEC peak/off-peak tariffs. Sample schedules and AED savings.
Read: Growatt Time of Use Solar Net Metering — Programming SPH for DEWA and SEC TOU Tariffs →Growatt Backup Power During a Grid Outage: SPH, SPF, ATS Box & Critical-Load Wiring
How Growatt SPH and SPF inverters deliver backup during a grid outage. ATS box requirements, critical-load panel wiring, transfer times and sizing examples.
Read: Growatt Backup Power During a Grid Outage: SPH, SPF, ATS Box & Critical-Load Wiring →