Growatt SPE 12000W
Growatt — the world's #1 residential solar inverter brand by Wood Mackenzie. The SPE 12000W is a European-spec hybrid storage inverter. Designed for European residential markets (Germany, Italy, Spain) and export-spec installations in Egypt and Lebanon.
- Max. recommended PV power (for module STC): 15000W
- Max. DC voltage: 550V
- Start voltage: 120V
In stock
Growatt SPE 12000W features
About the Growatt SPE 12000W
Growatt — the world's #1 residential solar inverter brand by Wood Mackenzie. The SPE 8000-12000 ES is a European-spec hybrid storage inverter. Designed for European residential markets (Germany, Italy, Spain) and export-spec installations in Egypt and Lebanon. Key features: VDE-AR-N 4105 compliant, HV battery compatible. 10-year warranty. Available across the Middle East, Europe, and Africa via Growatt MJS Solutions, the authorised distributor based in Dubai. Remote monitoring via the ShinePhone app and ShineServer cloud — view performance from anywhere, configure alerts, and manage multiple sites. This model: Max. recommended PV power (for module STC) 15000W.
Specifications last updated 1 May 2026
Growatt SPE 12000W full specifications
Electrical
| Max. recommended PV power (for module STC) | 15000W |
|---|---|
| Max. DC voltage | 550V |
| Start voltage | 120V |
| MPP voltage range | 60V-480V |
| No. of MPP trackers | 2 |
| No. of PV strings per MPP tracker | 1 |
| Max. input current per MPP tracker | 27A |
| AC nominal power | 12000W |
| Max. AC apparent power | 12000VA |
| Nominal AC voltage | 230V |
| AC grid frequency | 50/60Hz |
| Output current | 52.2A |
| Adjustable power factor | 0.8leading...0.8lagging |
| THDi | < 5% |
| Max. conversion efficiency (PV/AC) | 96.5% |
| European efficiency @ nominal (PV/AC) | 95.5% |
| Nominal DC voltage | 48V |
| Max charging and discharging current | 250A/280A |
| Type of battery | Lithium/Lead-acid |
| AC nominal output power | 12000W |
| Nominal AC output voltage | 230V |
| Nominal AC output frequency | 50/60Hz |
| Switch time | <30ms@Parallel |
| Peak efficiency | 96.5% |
| European efficiency | 95.5% |
| AC over current protection | Yes |
| AC over voltage protection | Yes |
| Ground fault monitoring | Yes |
| Grid monitoring | Yes |
| Anti-islanding protection | Yes |
| Residual-current monitoring unit | Yes |
| Insulation resistance monitoring | Yes |
| Surge protection | Yes |
Mechanical
| Dimensions (W / H / D) | 550/465/150mm |
|---|---|
| Weight | 21.5kg |
| Operating temperature range | -10°C...+50°C |
| Noise emission (typical) | <75dB |
| Max Short-Circuit Current per MPPT | 34A |
| Certifications | CE, NRS097 |
| Self-consumption | <75W |
| Topology | Transformerless |
| Cooling | DC fan |
| Protection degree | IP20 |
| Relative humidity | 5%~95% non-condensing |
| Altitude | <2000m |
| Communication | WiFi/4G |
Related Products

SPE 10000W
- Max. recommended PV power (for module STC):12500W
- Max. DC voltage:550V

SPE 8000W
- Max. recommended PV power (for module STC):10000W
- Max. DC voltage:550V


SPH 10000TL-HU
- Max. recommended PV power (for module STC):15000W
- Max. input power for single MPPT:10000W
Related Articles
Growatt vs Deye Inverters — Full 2026 Comparison for UAE and KSA Buyers
Detailed growatt vs deye inverters comparison: efficiency, battery flexibility, monitoring (ShinePhone vs SolarMan), warranty, regional support across the Gulf.
Read: Growatt vs Deye Inverters — Full 2026 Comparison for UAE and KSA Buyers →Growatt Time of Use Solar Net Metering — Programming SPH for DEWA and SEC TOU Tariffs
Growatt time of use solar net metering: program SPH inverters via ShinePhone for DEWA Shams Dubai TOU and SEC peak/off-peak tariffs. Sample schedules and AED savings.
Read: Growatt Time of Use Solar Net Metering — Programming SPH for DEWA and SEC TOU Tariffs →Growatt Backup Power During a Grid Outage: SPH, SPF, ATS Box & Critical-Load Wiring
How Growatt SPH and SPF inverters deliver backup during a grid outage. ATS box requirements, critical-load panel wiring, transfer times and sizing examples.
Read: Growatt Backup Power During a Grid Outage: SPH, SPF, ATS Box & Critical-Load Wiring →