Growatt MAX 100-125KTL3-X LV
Growatt — the world's #1 residential solar inverter brand by Wood Mackenzie. The MAX 100-125KTL3-X LV is a utility-scale three-phase string inverter. Designed for large rooftops, ground-mount solar farms, and IPP projects in KSA, Egypt, Jordan, and Morocco.
- Max. DC voltage: 1100V
- Start voltage: 195V
- Nominal voltage: 600V
In stock
Growatt MAX 100-125KTL3-X LV features
About the Growatt MAX 100-125KTL3-X LV
Growatt — the world's #1 residential solar inverter brand by Wood Mackenzie. The MAX 100-125KTL3-X LV is a utility-scale three-phase string inverter. Designed for large rooftops, ground-mount solar farms, and IPP projects in KSA, Egypt, Jordan, and Morocco. Key features: 1100V or 1500V DC, multi-MPPT, AFCI, smart cooling. 5-year warranty (extendable). Available across the Middle East, Europe, and Africa via Growatt MJS Solutions, the authorised distributor based in Dubai. Remote monitoring via the ShinePhone app and ShineServer cloud — view performance from anywhere, configure alerts, and manage multiple sites.
Specifications last updated 1 May 2026
Growatt MAX 100-125KTL3-X LV full specifications
Electrical
| Max. DC voltage | 1100V |
|---|---|
| Start voltage | 195V |
| Nominal voltage | 600V |
| MPP voltage range | 180V-1000V |
| No. of MPP trackers | 10 |
| No. of PV strings per MPP tracker | 2 |
| Max. input current per MPP tracker | 32A |
| Max. short-circuit current per MPP tracker | 40A |
| AC nominal power | 100000W / 110000W / 120000W / 125000W |
| Max. AC apparent power | 110000VA / 121000VA / 132000VA / 137500VA |
| Nominal AC voltage (range) | 220V/380V, 230V/400V (340-440V) |
| AC grid frequency (range) | 50/60 Hz (45-55 Hz / 55-65 Hz) |
| Max. output current | 158.4A@400V / 167.1A@380V / 174.6A@400V / 183.8A@380V / 190.5A@400V / 200.5A@380V / 198.5A@400V / 208.9A@380V |
| Adjustable power factor | 0.8leading...0.8lagging |
| THD | <3% |
| AC grid connection type | 3W/N/PE |
| Max. efficiency | 98.5% / 98.8% / 98.8% / 98.5% |
| European efficiency | 98.4% / 98.5% / 98.5% / 98.5% |
| MPPT efficiency | 99.9% |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| AC/DC surge protection | Type I / Type II |
| Insulation resistance monitoring | Yes |
| AC short-circuit protection | Yes |
| Ground fault monitoring | Yes |
| String detection | Yes |
| Anti PID function | Optional |
| Arc fault detection (AFCI) | Optional |
| Display | LED/WIFI+APP |
| Interfaces: RS485 / USB / PLC / GPRS / 4G / WiFi | Yes/Yes/Optional/Optional/Optional/Optional |
Mechanical
| Dimensions (W / H / D) | 970×640×345mm |
|---|---|
| Weight | 84kg |
| Operating temperature range | -30°C ... +60°C |
| Nighttime power consumption | < 1W |
| Topology | Transformerless |
| Cooling | Smart air cooling |
| Protection degree | IP66 |
| Relative humidity | 0–100% |
| Altitude | 4000m |
Related Articles
Growatt MAX Inverter Review: 50-125kW Industrial Three-Phase Tested
An EPC's Growatt MAX inverter review of the MAX 50-80KTL3 and MAX 100-125KTL3-X LV — 98.8% efficiency, 10 MPPT, IP66, and ROI on large Gulf rooftops.
Read: Growatt MAX Inverter Review: 50-125kW Industrial Three-Phase Tested →Growatt Inverter Error Codes Guide — 18 Faults and How to Fix Them
Complete diagnostic guide to the most common Growatt inverter error codes: DC Reverse, ISO Error, GFCI fault, Grid Loss, BUS overvoltage, and 13 more — causes, fixes, and field-tested checks.
Read: Growatt Inverter Error Codes Guide — 18 Faults and How to Fix Them →Growatt Low Solar Yield: 9-Step Troubleshooting Checklist (Shading, Soiling, MPPT & Derating)
Your Growatt system is underperforming? Diagnose low solar yield: panel shading, dirty modules, MPPT mismatch, inverter derating and string faults. Step-by-step checklist with expected output ranges.
Read: Growatt Low Solar Yield: 9-Step Troubleshooting Checklist (Shading, Soiling, MPPT & Derating) →