Growatt Solar Inverters MAX-100-125KTL3-X-LV
The MAX-100-125KTL3-X-LV is an utility-scale three-phase string inverter. Designed for large rooftops, ground-mount solar farms, and IPP projects in KSA.
Models and prices
- MAX-100-125KTL3-X-LVAED 29,093incl. VAT
Technical Specifications
| Parameter | MAX-100-125KTL3-X-LV |
|---|---|
| PV Input | |
| Max. DC voltage | 1100V |
| Start voltage | 195V |
| Nominal voltage | 600V |
| MPP voltage range | 180V-1000V |
| No. of MPP trackers | 10 |
| No. of PV strings per MPP tracker | 2 |
| Max. input current per MPP tracker | 32A |
| Max. short-circuit current per MPP tracker | 40A |
| Electrical Data | |
| AC nominal power | 100000W / 110000W / 120000W / 125000W |
| Max. AC apparent power | 110000VA / 121000VA / 132000VA / 137500VA |
| Max. output current | 158.4A@400V / 167.1A@380V / 174.6A@400V / 183.8A@380V / 190.5A@400V / 200.5A@380V / 198.5A@400V / 208.9A@380V |
| Max. efficiency | 98.5% / 98.8% / 98.8% / 98.5% |
| European efficiency | 98.4% / 98.5% / 98.5% / 98.5% |
| AC Output | |
| Nominal AC voltage (range) | 220V/380V, 230V/400V (340-440V) |
| AC grid frequency (range) | 50/60 Hz (45-55 Hz / 55-65 Hz) |
| Adjustable power factor | 0.8leading...0.8lagging |
| THD | <3% |
| AC grid connection type | 3W/N/PE |
| Efficiency | |
| MPPT efficiency | 99.9% |
| Protection Features | |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| AC/DC surge protection | Type I / Type II |
| Insulation resistance monitoring | Yes |
| AC short-circuit protection | Yes |
| Ground fault monitoring | Yes |
| String detection | Yes |
| Anti PID function | Optional |
| Arc fault detection (AFCI) | Optional |
| Communication | |
| Display | LED/WIFI+APP |
| Interfaces: RS485 / USB / PLC / GPRS / 4G / WiFi | Yes/Yes/Optional/Optional/Optional/Optional |
| Mechanical Data | |
| Dimensions (W / H / D) | 970×640×345mm |
| Weight | 84kg |
| Operating temperature range | -30°C ... +60°C |
| Nighttime power consumption | < 1W |
| Topology | Transformerless |
| Cooling | Smart air cooling |
| Protection degree | IP66 |
| Relative humidity | 0–100% |
| Altitude | 4000m |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Key Features & Technical Highlights
- 10 MPPTs fusefree design
- Smart I/V scan and diagnosis
- Intelligent string monitoring
- AC&DC type II SPD
- IP66 protection
Frequently Asked Questions
What are the AC output specifications of the Growatt MAX-100-125KTL3-X-LV inverter?
On the Growatt MAX-100-125KTL3-X-LV inverter, the nominal AC voltage (range) is 220V/380V, 230V/400V (340-440V), the AC grid frequency (range) is 50/60 Hz (45-55 Hz / 55-65 Hz), the adjustable power factor is 0.8leading...0.8lagging, the THD is <3% and the AC grid connection type is 3W/N/PE.
What are the PV input specifications of the Growatt MAX-100-125KTL3-X-LV inverter?
On the Growatt MAX-100-125KTL3-X-LV inverter, the max. DC voltage is 1100V, the start voltage is 195V, the MPP voltage range is 180V-1000V, the number of MPP trackers is 10 and the number of PV strings per MPP tracker is 2.
What are the efficiency specifications of the Growatt MAX-100-125KTL3-X-LV inverter?
On the Growatt MAX-100-125KTL3-X-LV inverter, the MPPT efficiency is 99.9%.
Which protection functions does the Growatt MAX-100-125KTL3-X-LV inverter have?
The Growatt MAX-100-125KTL3-X-LV inverter specification lists DC reverse polarity protection, DC switch, AC/DC surge protection (Type I / Type II), insulation resistance monitoring and AC short-circuit protection.
What are the dimensions, weight and enclosure specifications of the Growatt MAX-100-125KTL3-X-LV inverter?
On the Growatt MAX-100-125KTL3-X-LV inverter, the dimensions (W / H / D) are 970×640×345mm, the weight is 84kg, the topology is transformerless, the cooling is Smart air cooling and the protection degree is IP66.
What are the operating environment specifications of the Growatt MAX-100-125KTL3-X-LV inverter?
On the Growatt MAX-100-125KTL3-X-LV inverter, the operating temperature range is -30°C ... +60°C, the relative humidity is 0–100% and the altitude is 4000m.