InvertersModel MAX-80KTL3-LV
Growatt 80 kW Three-Phase On-Grid Solar Inverter MAX 80KTL3 LV
The MAX-80KTL3-LV is an utility-scale three-phase string inverter. Designed for large rooftops, ground-mount solar farms, and IPP projects in KSA.
- Max. recommended PV power (for module STC): 120000W
- Max. DC voltage: 1100V
- Start voltage: 250V
Choose the Max. recommended PV power (for module STC)
What sets the MAX-80KTL3-LV apart from the other 3 models in the family: Max. recommended PV power (for module STC) 120000W; Nominal voltage 600V; No. of MPPT trackers 7; AC nominal power 80000W; Max. AC apparent power 88800VA; Max. output current 128.8A; Max. efficiency 99%; European efficiency 98.5%.
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: free
- 10-year warranty
Growatt 80 kW Three-Phase On-Grid Solar Inverter MAX 80KTL3 LV features
High efficiency up to 99%
One-click diagnosis
String monitoring
AC & DC type II SPD
AFCI optional
About the Growatt 80 kW Three-Phase On-Grid Solar Inverter MAX 80KTL3 LV
The MAX-80KTL3-LV is an utility-scale three-phase string inverter. Designed for large rooftops, ground-mount solar farms, and IPP projects in KSA. Key features: 1100V or 1500V DC, multi-MPPT, AFCI, smart cooling. 10-year warranty (extendable). Available across the Middle East, Sudan and France through us, the authorised distributor based in Dubai. Remote monitoring via the ShinePhone app and ShineServer cloud — view performance from anywhere, configure alerts, and manage multiple sites.
Specifications last updated 23 July 2026
Growatt 80 kW Three-Phase On-Grid Solar Inverter MAX 80KTL3 LV full specifications
Electrical(31)
| Max. recommended PV power (for module STC) | 120000W |
|---|---|
| Max. DC voltage | 1100V |
| Start voltage | 250V |
| Nominal voltage | 600V |
| MPPT voltage range | 200V-1000V |
| No. of MPPT trackers | 7 |
| No. of PV strings per MPP tracker | 2 |
| Max. input current per MPP tracker | 26A |
| Max. short-circuit current per MPP tracker | 32A |
| AC nominal power | 80000W |
| Max. AC apparent power | 88800VA |
| Nominal AC voltage(range) | 220/380V, 230/400V (340-440V) |
| AC grid frequency(range) | 50/60 Hz (45-55Hz/55-65 Hz) |
| Max. output current | 128.8A |
| Adjustable power factor | 0.8leading ...0.8lagging |
| THDi | <3% |
| AC grid connection type | 3W+N+PE |
|---|---|
| Max. efficiency | 99% |
| European efficiency | 98.5% |
| MPPT efficiency | 99.9% |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| DC surge protection | Type I / Type II |
| Insulation resistance monitoring | Yes |
| AC short-circuit protection | Yes |
| Ground fault monitoring | Yes |
| Grid monitoring | Yes |
| Anti-islanding protection | Yes |
| Residual-current monitoring unit | Yes |
| String monitoring | Yes |
| AFCI protection | Optional |
Mechanical(14)
| Dimensions (W / H / D) | 860/600/300mm |
|---|---|
| Weight | 86kg |
| Operating temperature range | -25°C ... +60°C |
| Self-consumption | < 1W |
| Topology | Transformerless |
| Cooling | Smart air cooling |
| Protection degree | IP65 |
| Relative humidity | 0-100% |
|---|---|
| Altitude | 4000m |
| DC connection | H4/MC4(Optional) |
| AC connection | Cable gland+OT terminal |
| Display | LED+WiFi+APP |
| Interfaces: RS485 / USB | Yes/Yes /Optional/Optional/Optional |
| MB / RFI / RFS | Yes/Optional |
Downloads & support
Frequently Asked Questions
What are the AC output specifications of the Growatt MAX-80KTL3-LV inverter?
On the Growatt MAX-80KTL3-LV inverter, the AC nominal power is 80000W, the max. AC apparent power is 88800VA, the nominal AC voltage(range) is 220/380V, 230/400V (340-440V), the AC grid frequency(range) is 50/60 Hz (45-55Hz/55-65 Hz) and the max. output current is 128.8A.
What are the PV input specifications of the Growatt MAX-80KTL3-LV inverter?
On the Growatt MAX-80KTL3-LV inverter, the max. recommended PV power (for module STC) is 120000W, the max. DC voltage is 1100V, the start voltage is 250V, the MPPT voltage range is 200V-1000V and the number of MPPT trackers is 7.
What are the efficiency specifications of the Growatt MAX-80KTL3-LV inverter?
On the Growatt MAX-80KTL3-LV inverter, the max. efficiency is 99%, the European efficiency is 98.5% and the MPPT efficiency is 99.9%.
Which protection functions does the Growatt MAX-80KTL3-LV inverter have?
The Growatt MAX-80KTL3-LV inverter specification lists DC reverse polarity protection, DC switch, DC surge protection (Type I / Type II), insulation resistance monitoring and AC short-circuit protection.
What are the dimensions, weight and enclosure specifications of the Growatt MAX-80KTL3-LV inverter?
On the Growatt MAX-80KTL3-LV inverter, the dimensions (W / H / D) are 860/600/300mm, the weight is 86kg, the topology is transformerless, the cooling is Smart air cooling and the protection degree is IP65.
What are the operating environment specifications of the Growatt MAX-80KTL3-LV inverter?
On the Growatt MAX-80KTL3-LV inverter, the operating temperature range is -25°C ... +60°C, the relative humidity is 0-100% and the altitude is 4000m.