InvertersModel MAX-100KTL3-X2-LV
Growatt 100 kW Three-Phase On-Grid Solar Inverter MAX 100KTL3-X2 LV
The MAX-100KTL3-X2-LV is an utility-scale three-phase string inverter. Designed for large rooftops, ground-mount solar farms, and IPP projects in KSA.
- Max. DC voltage: 1100V
- Start voltage: 195V
- Nominal voltage: 600V
Choose the AC nominal power
What sets the MAX-100KTL3-X2-LV apart from the other 3 models in the family: AC nominal power 100000W; Max. AC apparent power 110000VA; Max. output current 158.8A@400V, 167.1A@380V; Max. efficiency 98.6%; European efficiency 98.4%.
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: free
- 5-year warranty
Growatt 100 kW Three-Phase On-Grid Solar Inverter MAX 100KTL3-X2 LV features
Max. string current up to 22.5A
Smart I/V scan and diagnosis
Intelligent string monitoring
AC&DC type II SPD
IP66 protection
About the Growatt 100 kW Three-Phase On-Grid Solar Inverter MAX 100KTL3-X2 LV
The MAX-100KTL3-X2-LV is an utility-scale three-phase string inverter. Designed for large rooftops, ground-mount solar farms, and IPP projects in KSA. Key features: 1100V or 1500V DC, multi-MPPT, AFCI, smart cooling. 5-year warranty (extendable). Available across the Middle East, Sudan and France through us, the authorised distributor based in Dubai. Remote monitoring via the ShinePhone app and ShineServer cloud — view performance from anywhere, configure alerts, and manage multiple sites.
Specifications last updated 23 July 2026
Growatt 100 kW Three-Phase On-Grid Solar Inverter MAX 100KTL3-X2 LV full specifications
Electrical(28)
| Max. DC voltage | 1100V |
|---|---|
| Start voltage | 195V |
| Nominal voltage | 600V |
| MPP voltage range | 180V-1000V |
| No. of MPP trackers | 8 |
| No. of PV strings per MPP tracker | 2 |
| Max. input current per MPP tracker | 45A |
| Max. short-circuit current per MPP tracker | 56.5A |
| AC nominal power | 100000W |
| Max. AC apparent power | 110000VA |
| Nominal AC voltage (range) | 220V/380V, 230V/400V (340-440V) |
| AC grid frequency (range) | 50/60 Hz (45–55 Hz/55–65 Hz) |
| Max. output current | 158.8A@400V, 167.1A@380V |
| Adjustable power factor | 0.8leading ... 0.8lagging |
| THD | <3% |
|---|---|
| AC grid connection type | 3W/N/PE |
| Max. efficiency | 98.6% |
| European efficiency | 98.4% |
| MPPT efficiency | 99.9% |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| AC/DC surge protection | Type II / Type II |
| Insulation resistance monitoring | Yes |
| AC short-circuit protection | Yes |
| Ground fault monitoring | Yes |
| String detection | Yes |
| Anti-PID function | Yes |
| Arc fault detection (AFCI) | Yes |
Mechanical(13)
| Dimensions (W / H / D) | 970/640/345mm |
|---|---|
| Weight | 84kg |
| Operating temperature range | -30°C ... +60°C |
| Nighttime power consumption | <1W |
| Topology | Transformerless |
| Cooling | Smart air cooling |
| Protection degree | IP66 |
| Relative humidity | 0–100% |
|---|---|
| Altitude | 4000m |
| DC connection | H4/MC4 (Max. 6mm²) |
| AC connection | OT terminal (Max. 240mm²) |
| Display | LED+WiFi+APP |
| Interfaces: RS485/USB/PLC/GPRS/4G/WiFi | Yes/Yes(Optional)/Optional/Optional/Optional/Optional |
Downloads & support
Frequently Asked Questions
What are the AC output specifications of the Growatt MAX-100KTL3-X2-LV inverter?
On the Growatt MAX-100KTL3-X2-LV inverter, the AC nominal power is 100000W, the max. AC apparent power is 110000VA, the nominal AC voltage (range) is 220V/380V, 230V/400V (340-440V), the AC grid frequency (range) is 50/60 Hz (45–55 Hz/55–65 Hz) and the max. output current is 158.8A@400V, 167.1A@380V.
What are the PV input specifications of the Growatt MAX-100KTL3-X2-LV inverter?
On the Growatt MAX-100KTL3-X2-LV inverter, the max. DC voltage is 1100V, the start voltage is 195V, the MPP voltage range is 180V-1000V, the number of MPP trackers is 8 and the number of PV strings per MPP tracker is 2.
What are the efficiency specifications of the Growatt MAX-100KTL3-X2-LV inverter?
On the Growatt MAX-100KTL3-X2-LV inverter, the max. efficiency is 98.6%, the European efficiency is 98.4% and the MPPT efficiency is 99.9%.
Which protection functions does the Growatt MAX-100KTL3-X2-LV inverter have?
The Growatt MAX-100KTL3-X2-LV inverter specification lists DC reverse polarity protection, DC switch, AC/DC surge protection (Type II / Type II), insulation resistance monitoring and AC short-circuit protection.
What are the dimensions, weight and enclosure specifications of the Growatt MAX-100KTL3-X2-LV inverter?
On the Growatt MAX-100KTL3-X2-LV inverter, the dimensions (W / H / D) are 970/640/345mm, the weight is 84kg, the topology is transformerless, the cooling is Smart air cooling and the protection degree is IP66.
What are the operating environment specifications of the Growatt MAX-100KTL3-X2-LV inverter?
On the Growatt MAX-100KTL3-X2-LV inverter, the operating temperature range is -30°C ... +60°C, the relative humidity is 0–100% and the altitude is 4000m.