Growatt Solar Inverters MIN-2500TL-XH2 / MIN-3000TL-XH2 / MIN-3600TL-XH2 / MIN-4200TL-XH2 / MIN-4600TL-XH2 / MIN-5000TL-XH2 / MIN-6000TL-XH2
The MIN-2500TL-XH2 is an on-grid single-phase string inverter. Designed for residential rooftop solar in UAE villas, KSA homes, and Middle East apartments.
Models and prices
- MIN-2500TL-XH2AED 2,366incl. VAT
- MIN-3000TL-XH2AED 2,366incl. VAT
- MIN-3600TL-XH2AED 2,717incl. VAT
- MIN-4200TL-XH2AED 2,753incl. VAT
- MIN-4600TL-XH2AED 2,777incl. VAT
- MIN-5000TL-XH2AED 2,801incl. VAT
Show all 7 models
- MIN-6000TL-XH2AED 2,885incl. VAT
Technical Specifications
| Parameter | MIN-2500TL-XH2 | MIN-3000TL-XH2 | MIN-3600TL-XH2 | MIN-4200TL-XH2 | MIN-4600TL-XH2 | MIN-5000TL-XH2 | MIN-6000TL-XH2 |
|---|---|---|---|---|---|---|---|
| Electrical Data | |||||||
| Max. recommended PV power (for module STC) | 5000W | 6000W | 7200W | 8400W | 9200W | 10000W | 10000W |
| Max. DC voltage | 500V | 500V | 550V | 550V | 550V | 550V | 550V |
| MPP voltage range | 40V-490V | 40V-490V | 40V-540V | 40V-540V | 40V-540V | 40V-540V | 40V-540V |
| Operating voltage range | 360-500V | 360-500V | 360-550V | 360-550V | 360-550V | 360-550V | 360-550V |
| Max. discharge power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
| AC nominal power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
| Max. output current | 11.3A | 13.6A | 16A | 19A | 20.9A | 22.7A | 27.2A |
| Max. efficiency | 98.2% | 98.2% | 98.2% | 98.4% | 98.4% | 98.4% | 98.4% |
| European efficiency | 97.1% | 97.1% | 97.2% | 97.2% | 97.5% | 97.5% | 97.5% |
| PV Input | |||||||
| Start voltage | 50V | ||||||
| Nominal voltage | 360V | ||||||
| No. of MPP trackers/strings per MPP tracker | 2/1 | ||||||
| Max. input current per MPPT | 16A | ||||||
| Max. short-circuit current per MPPT | 24A | ||||||
| Battery Input | |||||||
| Compatible battery | ARK XH Battery System (5.12kWh-17.9kWh), APX 5.0-30.0P-S0 (5kWh-30kWh) | ||||||
| Max. operating current | 17A | ||||||
| Max. charge power | 6000W | ||||||
| Additional Features | |||||||
| Max. AC apparent power | 2500VA | 3000VA | 3600VA | 4200VA | 4600VA | 5000VA | 6000VA |
| AC Output | |||||||
| Nominal AC voltage (range*) | 230V (180-280V) | ||||||
| AC grid frequency (range*) | 50/60 Hz (45-55Hz/55-65 Hz) | ||||||
| Adjustable power factor | 0.8leading...0.8lagging | ||||||
| THDi | <3% | ||||||
| AC grid connection type | Single phase | ||||||
| Efficiency | |||||||
| MPPT efficiency | 99.9% | ||||||
| Protection Features | |||||||
| DC reverse polarity protection | Yes | ||||||
| DC switch | Yes | ||||||
| DC/AC surge protection | Type II/Type II | ||||||
| Insulation resistance monitoring | Yes | ||||||
| AC short-circuit protection | Yes | ||||||
| Ground fault monitoring | Yes | ||||||
| Grid monitoring | Yes | ||||||
| Anti-islanding protection | Yes | ||||||
| Residual-current monitoring unit | Yes | ||||||
| AFCI protection | Optional | ||||||
| Communication | |||||||
| DC connection | H4/MC4(Optional) | ||||||
| AC connection | Connector | ||||||
| Display | OLED+LED/WIFI+APP | ||||||
| Interfaces: RS485/USB/WIFI/GPRS/ETH/LAN | Yes/Yes/Optional/Optional/Optional/Optional | ||||||
| Mechanical Data | |||||||
| Dimensions (W / H / D) | 375/350/160mm | ||||||
| Weight | 10.8kg | ||||||
| Operating temperature range | -30°C~+60°C | ||||||
| Altitude | 4000m | ||||||
| Self-consumption night | <3W | ||||||
| Topology | Transformerless | ||||||
| Cooling | Natural convection | ||||||
| Protection degree | IP66 | ||||||
| Relative humidity | 0%~100% | ||||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Key Features & Technical Highlights
- Max. efficiency 98.2%
- Dual MPP trackers
- Type II SPD on DC side
- String current up to 16A
- Battery ready, future proof
- 24h self-consumption monitoring
- Max. efficiency 98.4%
Frequently Asked Questions
What are the AC output specifications of the Growatt MIN-2500TL-XH2 inverter?
On the Growatt MIN-2500TL-XH2 inverter, the AC nominal power is 2500W, the max. AC apparent power is 2500VA, the nominal AC voltage (range) is 230V (180-280V), the AC grid frequency (range) is 50/60 Hz (45-55Hz/55-65 Hz) and the max. output current is 11.3A.
What are the PV input specifications of the Growatt MIN-2500TL-XH2 inverter?
On the Growatt MIN-2500TL-XH2 inverter, the max. recommended PV power (for module STC) is 5000W, the max. DC voltage is 500V, the start voltage is 50V, the MPP voltage range is 40V-490V and the number of MPP trackers/strings per MPP tracker is 2/1.
What are the battery specifications of the Growatt MIN-2500TL-XH2 inverter?
On the Growatt MIN-2500TL-XH2 inverter, the compatible battery is ARK XH battery system (5.12kWh-17.9kWh), APX 5.0-30.0P-S0 (5kWh-30kWh), the max. charge power is 6000W and the max. discharge power is 2500W.
What are the efficiency specifications of the Growatt MIN-2500TL-XH2 inverter?
On the Growatt MIN-2500TL-XH2 inverter, the max. efficiency is 98.2%, the European efficiency is 97.1% and the MPPT efficiency is 99.9%.
Which protection functions does the Growatt MIN-2500TL-XH2 inverter have?
The Growatt MIN-2500TL-XH2 inverter specification lists DC reverse polarity protection, DC switch, DC/AC surge protection (Type II/Type II), insulation resistance monitoring and AC short-circuit protection.
What are the dimensions, weight and enclosure specifications of the Growatt MIN-2500TL-XH2 inverter?
On the Growatt MIN-2500TL-XH2 inverter, the dimensions (W / H / D) are 375/350/160mm, the weight is 10.8kg, the topology is transformerless, the cooling is natural convection and the protection degree is IP66.