Growatt Hybrid Inverters SPA-10000TL3-BH-UP / SPA-4000TL3-BH-UP / SPA-5000TL3-BH-UP / SPA-6000TL3-BH-UP / SPA-7000TL3-BH-UP / SPA-8000TL3-BH-UP
The SPA-10000TL3-BH-UP is an AC-coupled storage inverter (retrofit). Designed for adding battery storage to existing PV systems in UAE villas without replacing the original inverter.
Models and prices
- SPA-10000TL3-BH-UPAED 4,847incl. VAT
- SPA-4000TL3-BH-UPAED 4,213incl. VAT
- SPA-5000TL3-BH-UPAED 4,213incl. VAT
- SPA-6000TL3-BH-UPAED 4,328incl. VAT
- SPA-7000TL3-BH-UPAED 4,472incl. VAT
- SPA-8000TL3-BH-UPAED 4,616incl. VAT
Technical Specifications
| Parameter | SPA-10000TL3-BH-UP | SPA-4000TL3-BH-UP | SPA-5000TL3-BH-UP | SPA-6000TL3-BH-UP | SPA-7000TL3-BH-UP | SPA-8000TL3-BH-UP |
|---|---|---|---|---|---|---|
| AC Output | ||||||
| AC nominal power | 10000W | 4000W | 5000W | 6000W | 7000W | 8000W |
| Max. AC apparent power | 10000VA | 4000VA | 5000VA | 6000VA | 7000VA | 8000VA |
| Nominal AC voltage (range) | 230/400V (310-477V) | |||||
| AC grid frequency (range) | 50Hz/60Hz (45Hz-55Hz/55Hz-65Hz) | |||||
| Max. output current | 15.2A | 6.1A | 7.6A | 9.1A | 10.6A | 12.1A |
| Adjustable power factor | 0.8leading...0.8lagging | |||||
| THDi | <3% | |||||
| AC grid connection type | 3W+N+PE | |||||
| Battery Input | ||||||
| Battery voltage range | 100–550V | |||||
| Max charging and discharging current | 25A | |||||
| Max charging and discharging power | 10000W | 4000W | 5000W | 6000W | 7000W | 8000W |
| Type of battery | Lithium/lead-acid | |||||
| Efficiency | ||||||
| Max. efficiency | 98.2% | 97.6% | 97.8% | 98.0% | 98.2% | 98.2% |
| European efficiency | 97.5% | 97.0% | 97.2% | 97.3% | 97.4% | 97.4% |
| Protection Features | ||||||
| AC surge protection | Type II | |||||
| Battery reverse protection | Yes | |||||
| AC short-circuit protection | Yes | |||||
| Ground fault monitoring | Yes | |||||
| Grid monitoring | Yes | |||||
| Anti-islanding protection | Yes | |||||
| Residual-current monitoring unit | Yes | |||||
| Insulation resistance monitoring | Yes | |||||
| General Specifications | ||||||
| Dimensions (W / H / D) | 505×453×198mm | |||||
| Weight | 30kg | |||||
| Operating temperature range | -25°C to +60°C | |||||
| Nighttime power consumption | <13W | |||||
| Topology | Transformerless | |||||
| Cooling | Natural | |||||
| Protection degree | IP65 | |||||
| Relative humidity | 0–100% | |||||
| Altitude | 3000m | |||||
| AC connection | Connector | |||||
| Display | LCD+LED | |||||
| Interfaces: RS485/CAN/USB | Yes | |||||
| Monitor: RF/WiFi/GPRS | Optional | |||||
| Additional Features | ||||||
| Switch time | <10ms | |||||
| Electrical Data | ||||||
| Warranty | 5 years (10 years optional) | |||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Key Features & Technical Highlights
- 100% three-phase imbalance output
- Smart phase-level power export limitation
- Wide battery voltage 100-550V
- UPS function, 10ms transition
- Scalable system configuration
Frequently Asked Questions
What are the AC output specifications of the Growatt SPA-10000TL3-BH-UP inverter?
On the Growatt SPA-10000TL3-BH-UP inverter, the AC nominal power is 10000W, the max. AC apparent power is 10000VA, the nominal AC voltage (range) is 230/400V (310-477V), the AC grid frequency (range) is 50Hz/60Hz (45Hz-55Hz/55Hz-65Hz) and the max. output current is 15.2A.
What are the battery specifications of the Growatt SPA-10000TL3-BH-UP inverter?
On the Growatt SPA-10000TL3-BH-UP inverter, the battery voltage range is 100–550V, the max charging and discharging current is 25A, the max charging and discharging power is 10000W and the type of battery is lithium/lead-acid.
What are the efficiency specifications of the Growatt SPA-10000TL3-BH-UP inverter?
On the Growatt SPA-10000TL3-BH-UP inverter, the max. efficiency is 98.2% and the European efficiency is 97.5%.
Which protection functions does the Growatt SPA-10000TL3-BH-UP inverter have?
The Growatt SPA-10000TL3-BH-UP inverter specification lists AC surge protection (Type II), battery reverse protection, AC short-circuit protection, ground fault monitoring and grid monitoring.
What are the dimensions, weight and enclosure specifications of the Growatt SPA-10000TL3-BH-UP inverter?
On the Growatt SPA-10000TL3-BH-UP inverter, the dimensions (W / H / D) are 505×453×198mm, the weight is 30kg, the topology is transformerless, the cooling is natural and the protection degree is IP65.
What are the operating environment specifications of the Growatt SPA-10000TL3-BH-UP inverter?
On the Growatt SPA-10000TL3-BH-UP inverter, the operating temperature range is -25°C to +60°C, the relative humidity is 0–100% and the altitude is 3000m.