Growatt MIN-2500TL-XH2 / MIN-3000TL-XH2 / MIN-3600TL-XH2 / MIN-4200TL-XH2 / MIN-4600TL-XH2 / MIN-5000TL-XH2 / MIN-6000TL-XH2
Growatt — the world's #1 residential solar inverter brand by Wood Mackenzie. The MIN 2500TL-XH2 is an on-grid single-phase string inverter. Designed for residential rooftop solar in UAE villas, KSA homes, and Middle East apartments.
Technical Specifications
| Parameter | MIN-2500TL-XH2 | MIN-3000TL-XH2 | MIN-3600TL-XH2 | MIN-4200TL-XH2 | MIN-4600TL-XH2 | MIN-5000TL-XH2 | MIN-6000TL-XH2 |
|---|---|---|---|---|---|---|---|
| Electrical Data | |||||||
| Max. recommended PV power (for module STC) | 5000W | 6000W | 7200W | 8400W | 9200W | 10000W | 10000W |
| Max. DC voltage | 500V | 500V | 550V | 550V | 550V | 550V | 550V |
| MPP voltage range | 40V-490V | 40V-490V | 40V-540V | 40V-540V | 40V-540V | 40V-540V | 40V-540V |
| Operating voltage range | 360-500V | 360-500V | 360-550V | 360-550V | 360-550V | 360-550V | 360-550V |
| Max. discharge power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
| AC nominal power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
| Max. output current | 11.3A | 13.6A | 16A | 19A | 20.9A | 22.7A | 27.2A |
| Max. efficiency | 98.2% | 98.2% | 98.2% | 98.4% | 98.4% | 98.4% | 98.4% |
| European efficiency | 97.1% | 97.1% | 97.2% | 97.2% | 97.5% | 97.5% | 97.5% |
| PV Input | |||||||
| Start voltage | 50V | ||||||
| Nominal voltage | 360V | ||||||
| No. of MPP trackers/strings per MPP tracker | 2/1 | ||||||
| Max. input current per MPPT | 16A | ||||||
| Max. short-circuit current per MPPT | 24A | ||||||
| Battery Input | |||||||
| Compatible battery | ARK XH Battery System (5.12kWh-17.9kWh), APX 5.0-30.0P-S0 (5kWh-30kWh) | ||||||
| Max. operating current | 17A | ||||||
| Max. charge power | 6000W | ||||||
| Additional Features | |||||||
| Max. AC apparent power | 2500VA | 3000VA | 3600VA | 4200VA | 4600VA | 5000VA | 6000VA |
| AC Output | |||||||
| Nominal AC voltage (range*) | 230V (180-280V) | ||||||
| AC grid frequency (range*) | 50/60 Hz (45-55Hz/55-65 Hz) | ||||||
| Adjustable power factor | 0.8leading...0.8lagging | ||||||
| THDi | <3% | ||||||
| AC grid connection type | Single phase | ||||||
| Efficiency | |||||||
| MPPT efficiency | 99.9% | ||||||
| Protection Features | |||||||
| DC reverse polarity protection | Yes | ||||||
| DC switch | Yes | ||||||
| DC/AC surge protection | Type II/Type II | ||||||
| Insulation resistance monitoring | Yes | ||||||
| AC short-circuit protection | Yes | ||||||
| Ground fault monitoring | Yes | ||||||
| Grid monitoring | Yes | ||||||
| Anti-islanding protection | Yes | ||||||
| Residual-current monitoring unit | Yes | ||||||
| AFCI protection | Optional | ||||||
| Communication | |||||||
| DC connection | H4/MC4(Optional) | ||||||
| AC connection | Connector | ||||||
| Display | OLED+LED/WIFI+APP | ||||||
| Interfaces: RS485/USB/WIFI/GPRS/ETH/LAN | Yes/Yes/Optional/Optional/Optional/Optional | ||||||
| Mechanical Data | |||||||
| Dimensions (W / H / D) | 375/350/160mm | ||||||
| Weight | 10.8kg | ||||||
| Operating temperature range | -30°C~+60°C | ||||||
| Altitude | 4000m | ||||||
| Self-consumption night | <3W | ||||||
| Topology | Transformerless | ||||||
| Cooling | Natural convection | ||||||
| Protection degree | IP66 | ||||||
| Relative humidity | 0%~100% | ||||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Max. efficiency 98.2%
- Dual MPP trackers
- Type II SPD on DC side
- String current up to 16A
- Battery ready, future proof
- 24h self-consumption monitoring
- Max. efficiency 98.4%
Frequently Asked Questions
Is the Growatt MIN 2500TL-XH2 approved for use in the UAE?
Yes — Growatt inverters are widely used in DEWA Shams Dubai, SEWA, FEWA, EtihadWE, and SEC Saudi Arabia installations. Verify the MIN 2500TL-XH2 on the latest DEWA Approved Equipment List before EPC submission. Growatt MJS Solutions can supply DEWA documentation on request.
What warranty comes with the Growatt MIN 2500TL-XH2, and is it valid in the Middle East?
10-Year Manufacturer Warranty, valid across every market we serve, including UAE, KSA, Oman, Bahrain, Qatar, Kuwait, Egypt, and the wider Middle East/North Africa. Extended warranty options are available at the time of purchase. All warranty claims are processed locally through Growatt MJS Solutions in Dubai.
How do I monitor the Growatt MIN 2500TL-XH2 remotely?
All Growatt inverters and batteries integrate with the ShinePhone mobile app and ShineServer cloud platform. Add a ShineWiFi-X dongle or use the built-in WiFi (depending on model) for real-time monitoring, alerts, and multi-site management. The app supports English, Arabic, and 20+ languages.
What is the maximum PV array size I can connect to the Growatt MIN 2500TL-XH2?
The MIN 2500TL-XH2 accepts up to 5000W of PV input. Growatt inverters typically support a DC/AC ratio up to 1.3–1.5 for optimal year-round yield in Middle East climates. Oversizing within this ratio compensates for high-temperature derating during UAE summers (rooftop temperatures often exceed 50 °C).
What's the lead time for the Growatt MIN 2500TL-XH2 in Dubai?
In-stock units typically ship within 1–2 business days from our Dubai warehouse. For larger orders or specific configurations, lead times of 2–4 weeks may apply. Contact Growatt MJS Solutions on +971 4 255 0887 or sales@growatinverter.com for an exact quote.
How does the Growatt MIN 2500TL-XH2 perform in UAE summer rooftop temperatures?
The MIN 2500TL-XH2 is rated -30 to 60 °C ambient. For UAE rooftops that pass 50 °C in summer, mount it in shade with good airflow and oversize the PV-to-AC ratio slightly to cover afternoon clipping. Its IP66 rating handles dust and humidity.
Is the Growatt MIN 3000TL-XH2 approved for use in the UAE?
Yes — Growatt inverters are widely used in DEWA Shams Dubai, SEWA, FEWA, EtihadWE, and SEC Saudi Arabia installations. Verify the MIN 3000TL-XH2 on the latest DEWA Approved Equipment List before EPC submission. Growatt MJS Solutions can supply DEWA documentation on request.
What is the maximum PV array size I can connect to the Growatt MIN 3000TL-XH2?
The MIN 3000TL-XH2 accepts up to 6000W of PV input. Growatt inverters typically support a DC/AC ratio up to 1.3–1.5 for optimal year-round yield in Middle East climates. Oversizing within this ratio compensates for high-temperature derating during UAE summers (rooftop temperatures often exceed 50 °C).
How does the Growatt MIN 3000TL-XH2 perform in UAE summer rooftop temperatures?
The MIN 3000TL-XH2 is rated -30 to 60 °C ambient. For UAE rooftops that pass 50 °C in summer, mount it in shade with good airflow and oversize the PV-to-AC ratio slightly to cover afternoon clipping. Its IP66 rating handles dust and humidity.
Is the Growatt MIN 3600TL-XH2 approved for use in the UAE?
Yes — Growatt inverters are widely used in DEWA Shams Dubai, SEWA, FEWA, EtihadWE, and SEC Saudi Arabia installations. Verify the MIN 3600TL-XH2 on the latest DEWA Approved Equipment List before EPC submission. Growatt MJS Solutions can supply DEWA documentation on request.