Growatt MAX 100-125KTL3-X LV
The Growatt MAX 100-125KTL3-X LV solar inverter is designed for superior energy conversion with a maximum DC voltage of 1100V and an AC nominal power of 100000W. Its advanced technology ensures high efficiency and reliability, making it an ideal choice for large-scale solar installations.
Technical Specifications
| Parameter | MAX 100KTL3-X LV | MAX 110KTL3-X LV | MAX 120KTL3-X LV | MAX 125KTL3-X LV |
|---|---|---|---|---|
| PV Input | ||||
| Max. DC voltage | 1100V | |||
| Start voltage | 195V | |||
| Nominal voltage | 600V | |||
| MPP voltage range | 180V-1000V | |||
| No. of MPP trackers | 10 | |||
| No. of PV strings per MPP tracker | 2 | |||
| Max. input current per MPP tracker | 32A | |||
| Max. short-circuit current per MPP tracker | 40A | |||
| AC Output | ||||
| AC nominal power | 100000W | 110000W | 120000W | 125000W |
| Max. AC apparent power | 110000VA | 121000VA | 132000VA | 137500VA |
| Nominal AC voltage (range) | 220V/380V, 230V/400V (340-440V) | |||
| AC grid frequency (range) | 50/60 Hz (45-55 Hz / 55-65 Hz) | |||
| Max. output current | 158.4A@400V / 167.1A@380V | 174.6A@400V / 183.8A@380V | 190.5A@400V / 200.5A@380V | 198.5A@400V / 208.9A@380V |
| Adjustable power factor | 0.8leading...0.8lagging | |||
| THD | <3% | |||
| AC grid connection type | 3W/N/PE | |||
| Efficiency | ||||
| Max. efficiency | 98.5% | 98.8% | 98.8% | 98.5% |
| European efficiency | 98.4% | 98.5% | 98.5% | 98.5% |
| MPPT efficiency | 99.9% | |||
| Protection Features | ||||
| DC reverse polarity protection | Yes | |||
| DC switch | Yes | |||
| AC/DC surge protection | Type I / Type II | |||
| Insulation resistance monitoring | Yes | |||
| AC short-circuit protection | Yes | |||
| Ground fault monitoring | Yes | |||
| String detection | Yes | |||
| Anti PID function | Optional | |||
| Arc fault detection (AFCI) | Optional | |||
| Mechanical Data | ||||
| Dimensions (W / H / D) | 970×640×345mm | |||
| Weight | 84kg | |||
| Operating temperature range | -30°C ... +60°C | |||
| Nighttime power consumption | < 1W | |||
| Topology | Transformerless | |||
| Cooling | Smart air cooling | |||
| Protection degree | IP66 | |||
| Relative humidity | 0–100% | |||
| Altitude | 4000m | |||
| Communication | ||||
| Display | LED/WIFI+APP | |||
| Interfaces: RS485 / USB / PLC / GPRS / 4G / WiFi | Yes/Yes/Optional/Optional/Optional/Optional | |||
Note: Specifications are based on the official Growatt datasheet. Values may be subject to change; always verify against the latest manufacturer documentation.
Key Features
10 MPPTs fusefree design
Smart I/V scan and diagnosis
Intelligent string monitoring
AC&DC type II SPD
IP66 protection
Applications & Use Cases
Typical Applications
- Residential solar systems
- Commercial installations
- Industrial solar plants
- Utility-scale projects
- Smart grid integration
Regional Installation Notes (Bahrain)
Climate Suitability: Ideal for Bahrain's hot climate with wide operating temperature range and dust-resistant design.
- Sand and dust resistant design
- Wide operating temperature range
- High efficiency in hot conditions
- Long-term warranty
Frequently Asked Questions
What is the maximum output power and efficiency rating of the Growatt MAX 100-125KTL3-X LV inverter?
The Growatt MAX 100-125KTL3-X LV inverter has a maximum AC apparent power of 110,000 VA and an AC nominal power of 100,000 W. It is designed to deliver high efficiency with a low Total Harmonic Distortion (THD) of less than 3%.
What are the PV input specifications for the Growatt MAX 100-125KTL3-X LV inverter?
The inverter supports a maximum DC voltage of 1100V, with a start voltage of 195V and a nominal voltage of 600V. The MPPT voltage range is between 180V and 1000V.
What are the AC output specifications of the Growatt MAX 100-125KTL3-X LV inverter?
The inverter provides a nominal AC voltage range of 220V/380V to 230V/400V, with an adjustable power factor from 0.8 leading to 0.8 lagging. It supports an AC grid frequency range of 50/60 Hz.
How many MPPT trackers and PV strings does the Growatt MAX 100-125KTL3-X LV inverter support?
The inverter is equipped with 10 MPPT trackers, each capable of supporting 2 PV strings, allowing for flexible and efficient solar panel configuration.
What protection features are included in the Growatt MAX 100-125KTL3-X LV inverter?
The inverter includes comprehensive protection features such as overvoltage, short-circuit, and overcurrent protection to ensure safe and reliable operation.
What communication and monitoring options are available with the Growatt MAX 100-125KTL3-X LV inverter?
The inverter supports various communication protocols and monitoring options, allowing for remote monitoring and management of the solar power system.
What is the warranty coverage for the Growatt MAX 100-125KTL3-X LV inverter?
Growatt typically offers a standard warranty for their inverters, which covers manufacturing defects and performance issues. Specific warranty terms should be confirmed with the supplier.
What are the installation requirements for the Growatt MAX 100-125KTL3-X LV inverter?
The inverter is designed for outdoor installation with an IP65 rating, suitable for various environmental conditions. It operates efficiently within a wide temperature range, ensuring reliable performance.