Growatt MIN-2500TL-X / MIN-3000TL-X / MIN-3600TL-X / MIN-4200TL-X / MIN-4600TL-X / MIN-5000TL-X / MIN-6000TL-X
Growatt — the world's #1 residential solar inverter brand by Wood Mackenzie. The MIN 2500TL-X is an on-grid single-phase string inverter. Designed for residential rooftop solar in UAE villas, KSA homes, and Middle East apartments.
Technical Specifications
| Parameter | MIN-2500TL-X | MIN-3000TL-X | MIN-3600TL-X | MIN-4200TL-X | MIN-4600TL-X | MIN-5000TL-X | MIN-6000TL-X |
|---|---|---|---|---|---|---|---|
| PV Input | |||||||
| Max. recommended PV power (for module STC) | 3750W | 4500W | 5600W | 6300W | 6900W | 7500W | 9000W |
| Max. DC voltage | 500V | 500V | 550V | 550V | 550V | 550V | 550V |
| Start voltage | 100V | ||||||
| Nominal voltage | 360V | ||||||
| MPP voltage range | 80V-550V | ||||||
| No. of MPP trackers | 2 | ||||||
| No. of PV strings per MPP tracker | 1 | ||||||
| Max. input current per MPP tracker | 13.5A | ||||||
| Max. short-circuit current per MPP tracker | 16.9A | ||||||
| AC Output | |||||||
| AC nominal power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
| Max. AC apparent power | 2500VA | 3000VA | 3600VA | 4200VA | 4600VA | 5000VA | 6000VA |
| Nominal AC voltage (range) | 230V (180-280V) | ||||||
| AC grid frequency (range) | 50/60 Hz (45-55Hz/55-65 Hz) | ||||||
| Max. output current | 11.3A | 13.6A | 16A | 19A | 20.9A | 22.7A | 27.2A |
| Adjustable power factor | 0.8leading...0.8lagging | ||||||
| THD | <3% | ||||||
| AC grid connection type | Single phase | ||||||
| Efficiency | |||||||
| Max. efficiency | 98.2% | 98.2% | 98.2% | 98.4% | 98.4% | 98.4% | 98.4% |
| European efficiency | 97.1% | 97.1% | 97.2% | 97.5% | 97.5% | 97.5% | 97.5% |
| MPPT efficiency | 99.9% | ||||||
| Protection Features | |||||||
| DC reverse polarity protection | yes | ||||||
| DC switch | yes | ||||||
| AC/DC surge protection | Type II / Type I | ||||||
| Insulation resistance monitoring | yes | ||||||
| AC short-circuit protection | yes | ||||||
| Ground fault monitoring | yes | ||||||
| Grid monitoring | yes | ||||||
| Anti-islanding protection | yes | ||||||
| Residual-current monitoring unit | yes | ||||||
| AFCI protection | Optional | ||||||
| Additional Features | |||||||
| DC connection | H4/MC4(Optional) | ||||||
| Mechanical Data | |||||||
| Dimensions (W / H / D) | 375/350/160mm | ||||||
| Weight | 10.8kg | ||||||
| Operating temperature range | -25°C ... +60°C | ||||||
| Noise emission (typical) | ≤35 dB(A) | ||||||
| Nighttime power consumption | <1W | ||||||
| Topology | Transformerless | ||||||
| Cooling | Natural convection | ||||||
| Protection degree | IP65 | ||||||
| Relative humidity | 0-100% | ||||||
| Altitude | 4000m | ||||||
| AC connection | Connector | ||||||
| Display | OLED+LED+WiFi+APP | ||||||
| Interfaces: RS485 / USB / WiFi / GPRS / RF / LAN | Yes/Yes/Optional/Optional/Optional/Optional | ||||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Lebanon
| Market | Lebanon |
| Grid authority / regulator | EDL Lebanon |
| Quotation currency | LBP |
| Support hours timezone | Asia/Beirut |
| Delivery & installation coverage | Beirut, Tripoli, Sidon |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Lebanon that is EDL Lebanon. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Maximum efficiency 98.2%
- Dual MPP trackers
- Type II SPD on DC side
- Supports export control
- Touch key and OLED display
- Data storage up to 25 years
- Maximum efficiency 98.4%
Frequently Asked Questions
Is the Growatt MIN 2500TL-X approved for use in the UAE?
Yes — Growatt inverters are widely used in DEWA Shams Dubai, SEWA, FEWA, EtihadWE, and SEC Saudi Arabia installations. Verify the MIN 2500TL-X on the latest DEWA Approved Equipment List before EPC submission. Growatt MJS Solutions can supply DEWA documentation on request.
What warranty comes with the Growatt MIN 2500TL-X, and is it valid in the Middle East?
5-Year Manufacturer Warranty, valid across every market we serve, including UAE, KSA, Oman, Bahrain, Qatar, Kuwait, Egypt, and the wider Middle East/North Africa. Extended warranty options are available at the time of purchase. All warranty claims are processed locally through Growatt MJS Solutions in Dubai.
How do I monitor the Growatt MIN 2500TL-X remotely?
All Growatt inverters and batteries integrate with the ShinePhone mobile app and ShineServer cloud platform. Add a ShineWiFi-X dongle or use the built-in WiFi (depending on model) for real-time monitoring, alerts, and multi-site management. The app supports English, Arabic, and 20+ languages.
What is the maximum PV array size I can connect to the Growatt MIN 2500TL-X?
The MIN 2500TL-X accepts up to 3750W of PV input. Growatt inverters typically support a DC/AC ratio up to 1.3–1.5 for optimal year-round yield in Middle East climates. Oversizing within this ratio compensates for high-temperature derating during UAE summers (rooftop temperatures often exceed 50 °C).
What's the lead time for the Growatt MIN 2500TL-X in Dubai?
In-stock units typically ship within 1–2 business days from our Dubai warehouse. For larger orders or specific configurations, lead times of 2–4 weeks may apply. Contact Growatt MJS Solutions on +971 4 255 0887 or sales@growatinverter.com for an exact quote.
How does the Growatt MIN 2500TL-X perform in UAE summer rooftop temperatures?
The MIN 2500TL-X is rated -25 to 60 °C ambient. For UAE rooftops that pass 50 °C in summer, mount it in shade with good airflow and oversize the PV-to-AC ratio slightly to cover afternoon clipping. Its IP65 rating handles dust and humidity.
Is the Growatt MIN 3000TL-X approved for use in the UAE?
Yes — Growatt inverters are widely used in DEWA Shams Dubai, SEWA, FEWA, EtihadWE, and SEC Saudi Arabia installations. Verify the MIN 3000TL-X on the latest DEWA Approved Equipment List before EPC submission. Growatt MJS Solutions can supply DEWA documentation on request.
What is the maximum PV array size I can connect to the Growatt MIN 3000TL-X?
The MIN 3000TL-X accepts up to 4500W of PV input. Growatt inverters typically support a DC/AC ratio up to 1.3–1.5 for optimal year-round yield in Middle East climates. Oversizing within this ratio compensates for high-temperature derating during UAE summers (rooftop temperatures often exceed 50 °C).
How does the Growatt MIN 3000TL-X perform in UAE summer rooftop temperatures?
The MIN 3000TL-X is rated -25 to 60 °C ambient. For UAE rooftops that pass 50 °C in summer, mount it in shade with good airflow and oversize the PV-to-AC ratio slightly to cover afternoon clipping. Its IP65 rating handles dust and humidity.
Is the Growatt MIN 3600TL-X approved for use in the UAE?
Yes — Growatt inverters are widely used in DEWA Shams Dubai, SEWA, FEWA, EtihadWE, and SEC Saudi Arabia installations. Verify the MIN 3600TL-X on the latest DEWA Approved Equipment List before EPC submission. Growatt MJS Solutions can supply DEWA documentation on request.